Code for library design?

What are the design specifications of the library?

1. Libraries with children's reading areas should have separate entrances and exits and outdoor children's activities venues with better facilities.

2. The basic coverage rate of new public libraries should not be greater than 40%. The greening rate should not be less than 30%.

3. The design of column size, height and load of each space in the library should have greater adaptability and flexibility in use. The combination of storage and reading space should adopt uniform column size, uniform height and uniform load. The column size should be suitable for the management method adopted and the arrangement requirements of the selected bookshelves. The column net of frame structure shall adopt integral multiple modulus of1.20m or1.25m. ..

4. The clear height of the reservoir area should not be less than 2.40m, and the clear height of the bottom should not be less than 2.30 m when there are beams or pipes; The clear height of the bottom surface of the structural beam (or pipe) of the stack room with stacked bookshelves should not be less than 4.70 meters.

5. When there is a reading room on the fourth floor and above of the library, it is advisable to set up a passenger elevator or a passenger and freight elevator.

6. The stacks on the second floor and above should have at least one set of books and periodicals lifting equipment. There should be no less than two sets of floors above. In addition to lifting equipment, stacks with six or more floors should be equipped with special freight elevators.

7. The clear width of the stairs dedicated for staff in the stacks should not be less than 0.8m, and the slope should not be greater than 45, and anti-skid measures should be taken.

8.300 lecture halls should be isolated from the reading area and set up independently. There should be at least two independent safety exits.

9. The fire resistance rating of libraries and stacks with books 1 10,000 volumes or more is Grade I ... The fire resistance rating of rare books in special collections is Grade I. ..

10. Libraries and stacks with a building height of more than 24m and a collection of no more than 1 10,000 volumes; Libraries and stacks with a building height of not more than 24.00 meters and a collection of more than 654.38+10,000 volumes but not more than 1 10,000 volumes shall have a fire resistance rating of not less than Grade II.

1 1. Basic stacks, non-book database, reading space integrating collection and reading. Maximum allowable building area: single floor ≯1500; For multilayer, ≯1000; ≯ 700 on the top; Basement or semi-basement library, 300. When the fire zone is equipped with automatic fire extinguishing system, the maximum allowable building area can be increased by 1.00 times according to the above regulations. When the automatic fire extinguishing system is installed locally, the increased area can be calculated as 1.00 times the local area.

12. Rare stacks and special collections should be provided with separate fire protection zones.

13. When the stacks with stacked bookshelves are divided into fire zones, the area of bookshelves shall be calculated together.

14. Libraries with more than 10,000 books 1 10,000 books, stacks and non-book databases with a building height of more than 24.00m, and rare stacks in the library should be equipped with a voluntary fire alarm system.

15. Evacuation staircases in stacks and non-stacks should be designed as closed staircases or smoke-proof staircases.

16. Each fire partition should have at least two exits for stacks, non-book databases and book collection space integrating collection and reading. However, if one of the following conditions is met, a safety exit can be set:

1) Special collections, film collections and rare books with a building area not exceeding 100m2.

2) Basement or semi-basement stacks with a building area not exceeding 100m2.

3) Except for two adjacent fire zones with underground and outdoor building areas exceeding 100m2, when there are fire doors connected on the firewall and the sum of the building areas of the two fire zones does not exceed 1.40 times the fire zone area;

4) Multi-storey stacks with an area not exceeding 300 square meters.