Want to build a gas station, Xi' an, where is the right place?

_ Ba National Wetland Park has open space to build gas stations.

First, apply for qualification.

1, which is in line with the development plan of urban gas station industry, has a stable supply channel for refined oil, and has signed an oil supply agreement with refined oil enterprises with wholesale business qualifications.

2. The design and construction of gas stations conform to the corresponding national standards, and the construction of gas stations conforms to the relevant national regulations on land management, fire safety and environmental protection.

3, professional and technical personnel with knowledge of refined oil inspection, measurement, storage and fire safety.

4. Water gas stations (ships) engaged in the supply and operation of marine refined oil shall comply with the relevant provisions on port and water traffic safety and water pollution prevention in addition to the above provisions.

Second, the bidding process:

1, on-site investigation, review of application materials, and site selection of various national standards and regulations.

2, to the local planning, fire protection, land, environmental protection and other departments to apply, sign the preliminary examination opinions, by the gas station where the county, city gas station authorities for preliminary examination.

3, through the preliminary examination, by Sinopec, PetroChina's local sales branch were reported to the provincial economic and Trade Commission for approval. For those who meet the requirements and pass the examination, the approval document for commencement shall be issued, and the owner shall go through the commencement formalities accordingly.

4. After the completion of the gas station construction, it meets the operating conditions of the gas station, and passes the acceptance of the competent department of the gas station in prefecture-level city and the provincial economic and trade commission, and issues the approval certificate for retail operation of refined oil products, and then goes through the industrial and commercial registration formalities with the approval certificate.

Extended data

Specific measures

1, grounding of anti-static facilities

Electrostatic grounding of gas station is to connect the oil storage tank, oil pipeline, tanker unloading platform and other facilities with the ground by wires, so that the conductor potential is close to the ground potential, and the unloading grounding wire should be equipotentially connected with the anti-static grounding body. Obviously, the purpose of grounding is to provide a channel for the electrostatic charge on the charged body to leak to the earth, so as to prevent the accumulation of electrostatic charge on the charged body or the increase of electrostatic potential.

Always check the grounding of the refueling gun and the connection of the flange on the pipeline to eliminate corrosion in time and ensure that the grounding resistance of the whole grounding system is not greater than 1008. Note: When three grounding systems (anti-static, lightning protection and power frequency electricity) share a grounding body, the grounding resistance should be selected according to the minimum value, generally 4 ~ 108.

2. Increase air humidity

Humidification mainly increases the leakage of static electricity along the surface of insulating medium, rather than increasing the leakage of static electricity. Humidification can not only accelerate the leakage of static electricity, prevent the accumulation of static electricity of hydrophilic substances, but also improve the minimum ignition energy of explosive mixture. In the gas station, steam or water is mainly sprayed into the refueling area, oil storage tank area, oil unloading area and tank car to keep the relative humidity in the gas station area within the range of 65% ~ 75%.

3. Doping will reduce the resistivity.

In order to effectively leak the static electricity on the charged body, the grounding method is only suitable for charged metal conductors or electrostatic conductors and sub-conductors, while increasing humidity is only effective for hydrophilic charged media. For electrostatic non-conductor with high resistivity, in order to effectively leak charge, it can only be solved by reducing its resistivity and improving its conductivity, that is, adding impurities that can reduce resistivity into dielectric materials such as fuel oil and plastic products to improve its conductivity.

Theoretical and experimental results show that when the resistivity of solid materials falls below 1098cm, static electricity can be effectively leaked and dangerous accumulation of static electricity can be prevented. For liquid, when its resistivity drops below 10 108cm, the electrostatic hazard can be eliminated. Antistatic agents commonly used in the market belong to chemical doping method. Antistatic agent has strong hygroscopicity and conductivity, which is worth popularizing and applying.

4. Ionized air method

Ionized air method is to ionize air by installing electrostatic neutralizer, and produce a large number of electric ions (usually positive and negative ion pairs) necessary to eliminate static electricity. Ionized air method is easy to use and does not affect fuel quality.

5. Control the degree of danger in the workplace.

Motor vehicle gas stations should install ventilation devices in closed and dangerous spaces to discharge explosive mixtures (such as possible oil mist) in time, so that the concentration of the mixture does not exceed the lower explosion limit.